ION Director requires 3 dosing pumps to operate! If you do not have 3 unused pumps, we recommend purchasing a IOND/Doser 2.1 set.
- Shown item is for ION Director and GHL Doser 2.1 SA, 4 pump set
- LATEST UPDATE ON SHIPPING: This item will ship approximately 3 months after order is placed.
Why buy from ReefBum? See below 🙂
Why buy from ReefBum?
Number one, I have been a hobbyist for over 25 years who wrote a book on reef keeping best practices……so I can leverage this wisdom to provide expert advise on equipment purchases.
Secondly, I am the sole proprietor and employee of this company who can be contacted any day of the week to answer your questions about equipment sold on reefbum.com. Therefore, you will always deal with the same person who actually uses the equipment you buy. And if I don’t have an immediate answer I can reach out to the manufacturer to get an answer….I have direct communication pipelines with all of them.
Yes, I am a “mom & pop” shop that will not always beat pricing from the “big box” online reef stores. But think of me as your personal reef tank concierge who is always on call to help figure out a problem or just chat about reef tanks. Now that’s priceless!
The precise and durable multi-ion sensor, specially developed by GHL for seawater analysis, requires no reagents, cost-effective calibration liquids are used for the automatic calibration. Inaccurate, time-consuming and costly measuring methods, such as test kits, are a thing of the past.
In addition to measurement, the ION Director® System offers many other functions:
- Control: Automatic readjustment of dosing pumps to keep a value stable
- Monitoring: Alarm when the value is outside an adjustable range
- Analysis: Display in charts and logbook (via app, cloud and web server GHL Connect and GHL Control Center).
Combine the ION Director® with the KH Director® and measure and control the KH value in addition to Ca, Mg, K, Na and NO3.
ION Director® – Features
Unique multi-ion sensor – Compact and precise multi-ion sensor in laboratory-grade quality, specially developed by GHL for seawater analysis, which combines the functions of several sensors.
No reagent liquids required – There is no need for reagent liquids for measuring.
Precise measurement – Extreme accuracy due to special electronics, sensors and measuring algorithms developed and perfected by GHL.
Cost-effective and harmless reference liquid – Economical measurements due to low consumption and inexpensive reference liquids.
Adjustable measurements per day – The number of measurements per day can be set, additional measurements can be started manually at any time.
Automatic calibration – In order to achieve the maximum possible accuracy, a fully automatic calibration of the sensor is carried out before each measurement.
Measured-value history – Utilizing the measurement value history, you can interpret past measurement results and react to fluctuations.
Automatic adjustment of dosing amounts – In order to achieve stable water parameters, ION Director® can automatically readjust dosing quantities of supplied liquids depending on the measurement result.
LED Status Display – The LED-illuminated GHL logo conveniently provides color-coded status indicators. The various colors show you the condition of your system at a glance.
- White = Configuration mode
- Blue = Normal operation
- Green = Measurement or dosing in progress
- Yellow = Warning threshold – fluid container(s) are running low
- Red = Alarm threshold – fluid container(s) are empty
WiFi, App and much more – GHL devices offer the most connectivity options, you can choose between app, cloud, web interface or PC software via WiFi/LAN or USB.
Seamless integration in the GHL system – Through the use of the PAB (ProfiLux Aquatic Bus) connection, IOND seamlessly integrates into the modular GHL system. The PAB connection ensures interference free communication with other GHL PAB-devices such as the GHL Doser 2.1 or the ProfiLux® 4.
Low maintenance design – The multi-ion sensor is easily accessible thanks to the well-thought-out design of the ION Director® and can be easily cleaned or replaced if necessary.
Measured values always available from anywhere – Find out about measurement results at any time and from anywhere – via app, cloud, web server or Windows software. Display additionally values and states on the ProfiLux 3/4 display or ProfiLux Touch, if present.
Robust device in laboratory quality – The design of the ION Director® meets laboratory requirements. Like all our instruments, it is made of high quality materials to ensure a long service life.
Technical Specifications
- Dimensions (mm): 220 x 150 x 75 mm (w/out sensor)
- Dimensions (in): 8.66″ x 5.9″ x 2.95″ (w/out sensor)
Scope of Delivery – ION Director® includes the following:
- Device with integrated measuring cell
- Multi-Ion sensor, especially designed for the IOND, incl. calibration liquids
- Silicone tube 5m
- Power-supply splitter-cable
ION Director pairs perfectly with the KH Director
The ION Director® can be used alone or in combination with the KH Director®.
With the IOND and KHD, you can fully automate the regulation of the aquarium’s key water parameters. While the KHD measures and controls alkalinity, the IOND covers other important parameters necessary to maintain a healthy reef.
How does the ION Director® work?
The IOND was designed as an accessory device and requires either a GHL Doser 2 Standalone or a ProfiLux aquarium controller (3 or 4) with GHL Doser 2 Slave to operate, see configurations below.
4 pump heads are required to perform the measurement.
To achieve the highest possible measurement accuracy, each test is performed with a freshly calibrated sensor. Two pump heads are used to convey the reference fluids required for this. After automatic calibration, a sample of the aquarium water is pumped into the ION Director®.
After the measurement has been completed, the sample water is pumped out again and collected in a separate container for later disposal.
How can the measured parameters be controlled?
Thanks to the innovative technology of the ION Director®, each parameter can be accurately measured and automatically regulated. If a parameter is too low or too high, the IOND can automatically calculate the amount by which dosages need to be changed to maintain stable values. It is therefore also suitable for different systems such as Balling® (Light) or Triton® .
Choose the optimal control mode for your aquarium and adjust it individually.
After a measurement, the deviation of the real value from the desired value (setpoint) is known. The following control modes operate on the basis of this deviation.
Add-On Control Mode
The set dosing quantities of certain dosing pumps are readjusted depending on the deviation determined, the user sets the quantity (in ml) by which the dosing quantity should change in the event of a certain deviation.
Adaptive control mode
Works similar to the Add-On control mode, but here the user determines the percentage change of the set dosing quantity for a certain deviation.
Configuration options
The ION Director® can be operated in two ways:
- The ION Director® is connected to the GHL Doser 2 (2.1) Standalone via the ProfiLux Aquatic Bus (PAB). In this configuration, the GHL Doser has control over the measuring process: It controls the dosing pumps and evaluates the measuring results.
- The ION Director® is connected to the ProfiLux (3 or 4) and a GHL Doser 2 (2.1) Slave via the ProfiLux Aquatic Bus (PAB). In this configuration the ProfiLux has control over the measuring process: It controls the dosing pumps in the Doser and evaluates the measuring results.
ION Director® Sets
Operation of the IOND requires always a GHL Doser with 4 pumps, depending on the configuration either as Slave or as Standalone version.
GHL offers these sets:
- IOND + GHL Doser 2.1 Standalone 4-way
- IOND + GHL Doser 2.1 Slave 4-way
The sets include a PAB cable (50 cm / 19.6″).
Get Social